Generator compatibility online UPS
EPO,ECO
USB,RS232,RJ11 option
SNMP card option
double conversion technology
SAKO SKG-VSERIESHF ONLINE UPS SPECIFICATION | | | | | |
APPLICATION: | | | | | | | | |
small network servers and other IT equipment | | | | | | | |
Features and Benefits | | | | | | | | |
1) High frequency and double conversion on-line technology | | | | | | |
2)Intelligent MCU control | | | | | | | | |
3) Wide input voltage range | | | | | | | | |
4) UPS start up without battery | | | | | | | | |
5) Cold start | | | | | | | | |
6) Advanced battery management | | | | | | | | |
7) Automatic battery charge in UPS off mode | | | | | | | |
8) Lightning and surge protection | | | | | | | | |
9) Short circuit and overload protection | | | | | | | | |
10) Fan speed auto control when loads varies | | | | | | | |
11) Optional extension battery pack | | | | | | | | |
12) EMI/RFI noise filter | | | | | | | | |
13) Smart RS232,USB,RJ45 communication with monitoring software | | | | | |
14) Optional SNMP Card slot | | | | | | | | |
15)with LCD and LED two type front panel | | | | | | | |
16)In LCD model, nominal bypass ECO setting function | | | | | | |
17)In LCD model, Generator setting function | | | | | | | |
18)In LCD model, Output voltage 220V,230V,240V setting function | | | | | |
19) EPO control system option | | | | | | | | |
| | | | | | | | |
| | | | | | | | |
| SKG-V1K | SKG-V1KS | SKG-V2K | SKG-V2KS | SKG-V3K | SKG-V3KS | SKG-V6K | SKG-V6KS |
Specifications |
Capacity(VA/W) | 1000VA/700W | 2000VA/1400W | 3000VA/2100W | 6000VA/4200W |
INPUT Feature |
Battery voltage(Vdc) | 24 | 48 | 96 | 144 |
Voltage Range(Vac) | 176~286VAC @ full load (138~300VAC @ half load) |
Frequency Range(Hz) | 46 ~ 54Hz / 56 ~ 64Hz |
Number of phases | single phase&earth ground |
Power Fator | ≥0.98, Full RCD Load |
Generator Input | Support |
Output feature |
Voltage | 220/230/240VAC± 1% |
Frequency ( Battery Mode ) | 50/60Hz ± 0.1 Hz |
Frequency(Hz) | 50±0.2% (battery mode) |
Wave form | Pure Sine wave THD<4% |
Overload Capacity(Line Mode) | >=110%; 2mins, Then transfer to bypass and Alarm, >=150%; 10 S, Then transfer to bypass, turn off output after 1mins and Alarm |
Overload capacity( Battery Mode ) | > =110 %; 30 S, Then turnoff output and Alarm, > =120 %; 1S, Then turnoff output and Alarm |
Output mode | IEC x2 | IEC x4 | IEC x4 | Terminal Block |
Battery |
Battery Type | 12V/9AH | Depending on the capacity of external batteries | 12V/9AH | Depending on the capacity of external batteries | 12V/5AH | Depending on the capacity of external batteries | 12V/9AH | Depending on the capacity of external batteries |
Numbers of Batteries | 2 | 4 | 8 | 12 |
Backup Time (Half Load) | >10 min | >10 min | >10 min | >12 min |
Recharge Time (to 90%) | 5 Hours | 5 Hours | 3Hours | 3Hours |
Charging Current (Max.) | 1.0A | 3.0A | 1.0A | 3.0A | 2.0A | 6.0A | 2.0A | 6.0A |
Rated Charging Voltage | 26.927.9vdc | 53.655.5vdc | 108111vdc | 161 ~164Vdc |
Other feature |
EFFICIENCY(AC /Battery Mode) | 93%-92% |
TRANSFER TIME(AC to DC) | Zero |
TRANSFER TIME(Inverter to Bypass) | 4ms (Typical ) |
AUDIBLE ALARM(Battery Mode) | Sounding every 4 seconds |
INDICATOR(LED Version) | Load Level / Battery Level / Battery Mode / AC Mode / Bypass Mode / Fault |
INDICATOR(LCD Version) | Load / Battery / Input / Output / Operating Mode Information |
Protections | Low battery protection,overload protection,short-circuit protection,overheated protection |
Ambient temperes | 0-40 |
Reative humidity | |
Products Size(mm) | L208*W145*H221mm | L462*W191*H298mm | L462*W191*H347mm | L526*W240*H489mm |
Products Weight(KG) | 12 | 5.2 | 23 | 10.8 | 25 | 12 | 90 | 35 |
High frequency Generator compatibility online UPS
Verified Information
This information is Verified by Bureau Veritas and validity period is
2012/05/11 --- 2013/05/11
All the information below may covers both Gold Supplier and its related companies , Their Relationship will be affirmed according to china laws and regulations , also it will be clearly display in the full report >>
Production Capacity:
Product line name
Production Line Capacity
Actual Units Produced(Previous Year)
Battery, Frequency converter, Inverter, Stabilizer, Switching power, UPS |
USD 46,153,900 |
confidential |
Export Market Distribution:
Market
Revenue(Previous Year)
Total Revenue (%)
North America |
confidential |
5.0 |
South America |
confidential |
2.5 |
Eastern Europe |
confidential |
5.0 |
Southeast Asia |
confidential |
10.0 |
Africa |
confidential |
5.0 |
Oceania |
confidential |
2.5 |
Mid East |
confidential |
5.0 |
Eastern Asia |
confidential |
5.0 |
Western Europe |
confidential |
2.5 |
Central America |
confidential |
2.5 |
Northern Europe |
confidential |
1.0 |
Southern Europe |
confidential |
1.0 |
South Asia |
confidential |
3.0 |
Domestic Market |
confidential |
50.0 |
Production Machinery:
Machine Name
Brand & Model No.
Quantity
Number of Year(s) Used
Condition
Hydraulic pressure bending machine |
WD67Y-63 |
1 |
4.5 |
Acceptable |
NC bending machine |
WD67K-100 |
1 |
4.0 |
Acceptable |
Shearing plate machine |
QC12Y |
3 |
4.0 |
Acceptable |
Punch machine |
J23-63 |
24 |
3.5 |
Acceptable |
Coiling line machine |
No information |
18 |
4.0 |
Acceptable |
Wave crest welding machine |
JK-300DS |
1 |
2.0 |
Acceptable |
Testing Machinery:
Machine Name
Brand & Model No.
Quantity
Number of Year(s) Used
Condition
Voltage resistance tester |
WB2670A |
12 |
3.5 |
Acceptable |
Leakage current tester |
WB2675 |
1 |
3.0 |
Acceptable |
Resistance on earth tester |
CC2520 |
2 |
4.0 |
Acceptable |
Insulated tester |
CC2680 |
1 |
4.0 |
Acceptable |
Composite testing board |
No information |
1 |
4.0 |
Acceptable |
Multi-functional testing board |
No information |
1 |
4.5 |
Acceptable |
Production Flow:
1.Raw material inspection
2.Punch
3.Coiling
4.Assembly 1
5.Assembly 2
6.Inspection
7.Aging
8.Testing
9.Package
Certification:
Certified Picture
Certification Name
Certified By
Certificate No.
Product Name & Model No.
Available Date-Expired Date
|
CCC |
Police Fire Fighting Product Assessment Center |
2012081801000305 |
Emergency Power Supply for Fire Fighting & FEPS-SK-22-KVA, FEPS-SK-30-KVA, FEPS-SK-37-KVA, FEPS-SK-45-KVA, FEPS-SK-55-KVA, FEPS-SK-75-KVA, FEPS-SK-95-KVA,FEPS-SK-11-KVA, |
2012/03/14 --- 2013/12/19 |
|
CCC |
Police Fire Fighting Product Assessment Center |
2012081801000306 |
Emergency Power Supply for Fire Fighting & FEPS-SK-3-KVA, FEPS-SK-0.5-KVA, FEPS-SK-1-KVA, FEPS-SK-2-KVA, FEPS-SK-4-KVA, FEPS-SK-5-KVA, FEPS-SK-7-KVA, FEPS-SK-6-KVA, FEPS-SK-8-KVA, FEPS-SK-9-KVA, FEPS-SK-10-KVA |
2012/03/14 --- 2013/12/19 |
|
CCC |
Police Fire Fighting Product Assessment Center |
2012081801000304 |
Emergency Power Supply for Fire Fighting & FEPS-SK-5.5-KVA, FEPS-SK-3.7-KVA, FEPS-SK-7.5-KVA, |
2012/03/14 --- 2013/12/19 |
Testing Report:
Report Picture
Report Name
Report By
Product Name & Model No.
Report Date
|
Test Report |
Zhejiang Fangyuan Test Group Co., Ltd. |
Auto AC stabilizer & SVC-1000VA |
2011/09/01 |
|
Test Report |
Zhejiang Fangyuan Test Group Co., Ltd. |
AC Stable Power Supply & SVD-500VA |
2008/12/12 |
|
Test Report |
National Fire Fighting electronic Quality Inspection Center |
Emergency Power Supply for Fire Fighting & FEPS-SK-7.5-KVA |
2011/04/13 |